MTS - Modified Tyrodes Solution (1000 ml) - Ready to use
LRE-S-LSG-1002-1Modified Tyrode's Solution for use with mammalian heart tissue.
Product information
- Ready to Use MTS solution
- Carbogen (95% oxygen and 5% carbon dioxide) supply is necessary for proper Bicarbonate pH buffering.
-
autoclaved
Instructions for use:
Ready to use:
For 1000 ml MTS Solution:
- Oxygenate 500 ml Base A for 10 min
- Add slowly 500 ml Base B
- Oxygenate ACSF Solution during use
pH 7.4 when oxygenated with 95% O2, 5% CO2 (Carbogene)
Use immediately once opened. Store at 4 - 8 °C
Ional composition of MTS Solution (Base A + Base B)
NaCl = 126,7 mM
KCl = 5,4 mM
CaCl2 = 1,8 mM
MgCl2 = 1,05 mM
NaH2PO4 = 0,42 mM
NaHCO3 = 22 mM
Glucose = 5 mM
We Also Recommend